High Reliability Processing & Selection

Radiation Hardness Assessment of Isocom Optocouplers by British Aerospace (42K)
Home Page

Isocom products have been independently assessed by British Aerospace, Bristol. A detailed report is available on request.

4N55 6N134 6N140A
Neutron Fluence Hard To > 3E12 n/cm2 > 1E13 n/cm2 > 3E12 n/cm2
Total Dose Hard To 1 Mrad (Si) 1 Mrad (Si) 30 krad @ If=0.5mA
0.1 Mrad @ If=1.5mA
1 Mrad @ If=5mA
Dose Rate Hard To 6E9 rad (Si)/sec
Vcc photocurrent up to 1.6 A 1.5 A 5.2 A
Output transient upset up to 5 µs 15 µs 9 µs
©2006 ISOCOM LTD